Group: [G-2815] Southern Georgia Regional Commission
Site: [S-6669] New River
Filter dates between and
Date/Time 2/7/2020 12:00:00 PM 3/2/2020 4:07:00 PM 4/11/2020 10:10:00 AM 5/11/2020 12:30:00 PM 5/20/2020 3:10:00 PM 6/3/2020 2:34:00 PM 7/3/2020 10:58:00 PM 8/4/2020 1:20:00 PM 8/6/2020 11:15:00 AM 9/1/2020 11:22:00 AM 9/11/2020 11:35:00 AM 9/18/2020 12:58:00 PM 10/6/2020 8:30:00 AM 11/9/2020 11:35:00 AM 11/18/2020 11:10:00 AM 12/7/2020 12:38:00 PM 1/8/2021 11:28:00 PM
Time spent monitoring
minutes
48 20 35 30 30 26 13 21 12 15 15 18 12 15 18 12 13
3M E coli
cfu/100 mL
500 133 33 66 766 100 133 33 33 100 66 166 66 33 - 166 266
Air Temperature
°C
12 17 19 22 22 28 28 33 21 28 23.5 24.5 16 23.5 26 14.5 16
Conductivity
µs/cm
110 130 110 120 50 120 100 100 140 130 170 100 150 170 160 130 80
Dissolved Oxygen
mg/L
8.55 8.85 6.85 7.95 5.6 7.7 6.2 6 7.35 3.8 7.3 6.2 6.4 7.3 9.25 9 9
DO %Saturation
%
86.1 89.12 73.63 92.47 63.87 93.98 79.34 82.84 81.35 50.5 82.43 74.24 65.86 82.43 89.09 85.71 86.69
pH
6 6.75 7 7 6.5 6.75 6.5 7.5 7 7 6.75 7 6.75 6.75 7 6.75 6.5
Water Temperature
°C
16 16 18.5 23 22 25.5 28 32 20.5 30 21.5 24.5 17 21.5 14 13.5 14
Event ID 81056 form 81066 form 81035 form 81082 form 81139 form 81233 form 81570 form 82353 form 83408 form 82786 form 86523 form 83021 form 87228 form 83680 form 83953 form 84021 form 86373 form
Select a different parameter to put it on the secondary axis.:    
Display:
3M E coli, cfu/100 mL (range 33 - 766, average 166.25)